Calicore first reviews the design question, material, specification, required units, target density and moisture, and whether a point result or dry-out curve is needed. Representative soil, backfill, concrete, grout, or slurry samples can then be labeled, sealed, and shipped from Topeka.
The specimen is logged and prepared at the agreed condition. A transient needle probe measures thermal response, and the report identifies the material, preparation, moisture, density, measured points, units, and limitations. For a field survey, the same traceability is maintained at mapped in-place test locations.
ASTM D5334 is the test method commonly used for suitable soil and soft-rock materials; IEEE 442 provides broader guidance for soil and backfill thermal measurements and cable applications. The governing project specification decides what is required.